Our team is specializing in fuel cell test station custom design. We work together with our customers to identify their testing needs and make sure that they will be included in the test station design.

TEST STATION HIGHLIGHTS
Any of the Dynamic Test Stations designs suggested on this page can be custom designed, based on future customers’ requirement documentation and their testing needs.
DETAILED USER FUNCTIONAL EXPECTATIONS - as required
-
Steady State Polarizations: 0 to “Maximum Load” (Amps) (30%RH 100%RH; 60C, 90C)
-
Temperature Sensitivity (50C to 90C)
-
Fast Transient Polarization (FTP)
-
RH Sensitivity (20% to 100%RH)
-
Voltage Cycling
-
Cycling voltammetry
-
Start up/ Shut Down (SU/SD) - this will include a cycle where current is drawn, turned off, anode air purge, then regular operation. Data acquisition to be minimum 0.1s.
-
Voltage Reversal testing